HP ESG-D Series: Option H99 Improved ACP for IS-95 CDMA, W-CDMA and TETRA

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
Option H99 is designed to improve adjacent channel power performance (ACP or spurious emissions) of 3 and 4 GHz HP ESG-D Series RF Signal Generators (HP E4432B and E4433B) for IS-95 CDMA, W-CDMA and TETRA applications.

To provide you with a complete product solution and protect your investment in the HP-ESG-series RF signal generator family, HP provides:

Optional services include customized, practical education for users including wireless technology basics and HP ESG applications.

A complete overview of the HP ESG Family is provided at: HP ESG Family of Digital and Analog RF Signal Generators.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Supplemental Specifications for HP E4432B or E4433B instruments with Option H99

Spurious Emissions for IS-95 CDMA (with high crest factor on) with Option UN5: Channels/Offsets .885 to 1.25 MHz 1.25 to 1.98 MHz 1.98 to 5 MHz1 Std UNB H99 Std UNB H99 Std UNB H99 Reverse (at <=0 dBm) 30-200 MHz -66(-72) -70(-75) -71(-73) (-76)(-78)(-74) (-79)(-79)(-77) 700-1000 MHz -68(-73) -72(-76) -78(-79) (-76)(-79)(-82) (-79)(-79)(-79) 1000-2000 MHz -63(-66) -70(-74) -78(-79) (-70)(-78)(-82) (-79)(-79)(-79) 9/64 channels (at <=-2 dBm) 30-200 MHz -65(-68) -68(-71) -70(-72) (-73)(-76)(-72) (-78)(-78)(-77) 700-1000 MHz -64(-70) -69(-73) -73(-75) (-75)(-77)(-79) (-79)(-79)(-79) 1000-2000 MHz -60(-63) -67(-71) -72(-74) (-68)(-75)(-78) (-78)(-78)(-78) 1Specifications apply with high crest factor off Adjacent Channel Power for W-CDMA with Option H97: (fc 1800 to 2200 MHz, at 4.096 Mchip/sec, typical, <=–2 dBm, at 25 ±5 °C) Standard Option UNB Option H99 1 DTCH: –58 dBc –58 dBc –63 dBc 20 DTCH: –50 dBc –56 dBc –62 dBc Adjacent Channel Power for W-CDMA with Option H98: (fc 1800 to 2200 MHz, at 4.096 Mchip/sec, typical, <=–2 dBm, at 25 ±5 °C) 1 DTCH: –61 dBc (-63 dBc) Adjacent Channel Power for TETRA with Option UN8: (In 25 kHz bandwidth, with 18 kHz root Nyquist filter, at power levels <=4 dBm; <=8 dBm with UNB) Continuous Mode: -72 dBc The following specifications are different than the standard specifications of the base instrument Output Power 250 kHz to 3 GHz +10 to -136 dBm >3 GHz +4 to -136 dBm Level Accuracy Specifications degrade by 0.2 dB With digital modulation <3 GHz specifications apply at <+7 dBm >3 GHz specifications apply at <+4 dBm Non harmonics (<+4 dBm) <-53 dBc at offsets >3 kHz AM Specifications are typical up to 3 GHz, Not specified above 3 GHz Pulse Modulation >60 dB on/off ratio at fc <250 MHz Refer to the HP ESG Series "Technical Specifications" under Key Literature for base instrument specifications.

Declarations of Conformity


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP ESG-D Series RF Signal Generator Option H99
Requires one of the following RF signal generators:
HP E4432B     ESG-D Series RF Signal Generator, 250 kHz to 3 GHz
HP E4433B     ESG-D Series RF Signal Generator, 250 kHz to 4 GHz
   Opt H99    Improved ACP performance for TETRA, CDMA and W-CDMA
              (Not compatible with Options UNA, UNB or H03)
   Opt 1CM    Rackmount kit
   Opt 1CN    Handle kit
   Opt 1CP    Rackmount and handle kit
   Opt 1E5    High stability timebase
   Opt 1EM    Rear-mounted connectors
   Opt UND    Internal dual arbitrary waveform generator
              (Not compatible with Options H03 or H98)
   Opt UN8    Real-time I/Q baseband generator with TDMA standards and 1M RAM
              (Not compatible with Options H03 or H98)
   Opt UN9    Adds 7M RAM to Option UN8
              (Requires Option UN8; not compatible with Options H03 or H98)
   Opt UN7    Internal bit-error-rate (BER) analyzer
              (Requires Option UN8; not compatible with Options H03 or H98)
   Opt UN5    Multichannel CDMA personality
              (Requires Option UND; not compatible with Options H03 or H98)
   Opt H97    Multichannel W-CDMA personality
              (Requires Option UND; not compatible with Options H03 or H98)
   Opt H98    Real-time W-CDMA for Receiver tests
              (Not compatible with Options UNB, UND, UN5, UN7, UN8, H03 or H97)


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP RF Signal Generators Options For The HP ESG Family ( PDF)
HP ESG Series RF Digital and Analog Signal Generators, Brochure ( PDF)
HP ESG Series RF Signal Generators, Technical Specifications ( PDF)
HP ESG Series RF Signal Generators, Configuration Guide ( PDF)

If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. Get Acrobat

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
Additional help is a click away!

Want to talk to a knowledgeable engineer about this product at our HP Test and Measurement Call Center? Do you have a question you want to send in by e-mail? A measurement set-up you need to fax in? Follow the link above and you will be given a choice to contact an engineer by telephone, e-mail or fax.

This service is available only in the United States. For assistance outside the U.S., contact your local HP DIRECT or HP Sales Office.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related Information:


Related HP ESG Family of Digital and Analog RF Signal Generators product datasheets:

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Thursday February 18 09:43:02 UTC 1999