HP E4859A Serial Cell Generator and Analyzer System![]()
|
Generation of all Types of Burst-Mode Data
Multiple HP E4854A dual serial cell generators can be set up to emulate
burst-mode data in a network. Cell length, cell content and cell timing
can be varied for each generator to allow characterization of the
transmission performance under real network conditions, even for designs
using proprietary cell formats.
Error Performance Analysis of Burst-Mode Data
The HP E4853A serial cell analyzer measures the bit-error performance
of burst-mode cells coming from one of the generators. Both the generator and
analyzer are synchronized through auto-adjust.
HP E4854A provides two serial cell generators HP E4853A provides one serial cell analyzer and one generator Bit-rate: 170 kb/s to 250 Mb/s, Opt 660 Mb/s Cell Content: Up to 28 segments of user-defined pattern and/or PRBS User-Defined Pattern: 64 Kb per channel PRBS: 2'-1 to 2"-1 Segment Length: 1 bit to 64 Kb Guardtime Between Cells in Burst-Mode: 0 to 24 ms, resolution 10 ps Output Amplitude: 0.3 V to 2.5 V, TTL, ECL, PECL Auxiliary Output (optional): Cell envelope, bursted clock, continuous clock Auto-Adjust: Synchronization of analyzer and generator compensates for cell transfer delays Measurements: Bit error count, bit error ratio (individual cell segments can be selected) Decision Threshold Voltage: -2.1 V to +5.1 V Module Size: VXI-C-size, 1-slot
HP E4859A Entry System Serial Cell Generator and Analyzer (nine free slots) HP E4853A Serial Cell Generator/Analyzer Module (one slot) HP E4854A Dual Seial Cell Generator Module (one slot) Opt 660 Bit-rate 660 Mb/s max Opt 001 Auxiliary Output Opt ABJ Japanese localization Opt WOI 1 Year On-site Warranty Opt UK6 Commercial Calibration Opt + UAH S/W Updates and LicenseAll orders include the following:
One entry system is needed. Optionally the free slots can be used for additional HP E4853A and HP E4854A modules. For assistance in defining your configuration, please contact your local Hewlett-Packard sales office.
The entry system comes pre-installed and includes mainframe, clock source and sequencer, one HP E4853A (one generator/one analyzer) module, controller with operating system, application software licenses, and documentation. Monitor, keyboard, and mouse have to be ordered separately.
Technical Data Sheet
( PDF)
Product Overview
( PDF)
Configuration Guide
( PDF)
If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. |
![]() |
Related product families available online:
Page Updated: Thursday February 18 05:43:19 UTC 1999