![]() | ||||
![]() |
HP E8460A 256-Channel Relay Multiplexer![]()
|
The HP E8460A can be programmed into individual topologies; some common examples are shown in the table below. Many other combinations of these topologies are supported (in addition to those shown in the table). two-wire, three-wire, and four-wire measurements can be configured.
Refer to the Related Links Section below for instrument driver availability and downloading instructions, as well as for recent product updates, if applicable.
VXI Characteristics
VXI device type: Register based Data transfer bus: A16, slave only Size: C Slots: 1 Connectors: P1/P2 Shared memory: None VXI busses: None C-size compatibility: n/a
Instrument Drivers
See the HP Website (http://www.hp.com/go/inst_drivers) for driver availability and downloading. Command module firmware: Downloadable Command module firmware rev: A.08 I-SCPI Windows® 3.1: No I-SCPI Series 700: No C-SCPI LynxOS: No C-SCPI Series 700: No HP Panel Drivers: No VXIplug&play Windows Framework: No VXIplug&play Windows 95/NT® Framework: Yes VXIplug&play HP-UX Framework: 10.2 planned 1998
Module Current
IPM (A) IDM (A) +5 V: 1.7 0.4 +12 V: 0 0 –12 V: 0 0 +24 V: 0 0 –24 V: 0 0 –5.2 V: 0 0 –2 V: 0 0
Cooling/Slot
Watts/slot: 8.5 DeltaP mm H2O: 0.05 Air Flow liter/s: 0.7
HP E8460A 256-Channel Relay Multiplexer* Opt 012 Crimp and Insert Terminal Block** Opt 014 Fault Tolerant Terminal Block*** Opt 015 Ribbon Cable Connector Terminal Block*** Opt 0B3 Service Manual Opt W01 3 Year Return to HP to 1 Year OnSite Warranty * Note: Standard unit does not include terminal block. One of the terminal block options must be ordered. ** Note: Crimp-and-Insert Contacts are not included. See the Interconnect and Wiring section for information on ordering Crimp-and-Insert Contacts. *** Note: Ribbon cables and and mating connector are not included. See ordering information below:Recommended 3M Mating Socket and Cable Qty Required per Part Description Terminal Card 3M Part Number ---------------- ---------------- -------------- socket (without 3414-6600 strain relief) 8 sockets either with or without socket* (with strain relief 3414-6606 strain relief) metal strain 8* 3448-2034 relief* (low profile) flat cable (34 length as needed 3365/34 conductor) * Required only for socket with strain relief Manufacturer Ordering Information Contact 3M to obtain ordering information as follows: 3M Electronic Products Division 6801 River Place Blvd. Austin, TX 78726-9000 telephone 800-225-5373
Trademarks:
Windows and NT are U.S. registered trademarks of Microsoft Corporation.
HP E8460A Technical Specifications Datasheet
If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. |
![]() |
Related Information:
Related VXI Relay Multiplexer Modules product datasheets:
Related product families available online:
Page Updated: Thursday November 05 21:19:47 UTC 1998