HP J2527A Transmission Impairment Measurement Set![]()
|
The HP J2527A TIMS interface includes the following features:
Except where otherwise stated, the following parameters are warranted performance specifications. Parameters described as “typical” or “normal” are supplemental characteristics which provide a useful indication of typical, but non-warranted, performance characteristics.
Measurements
Measurement methods meet IEEE Std 743-1984
Transmitter Frequency Range: 50 to 99999 Hz Resolution: 1 Hz Accuracy: +/- 50 ppm
Range: 100 to 200 kHz Resolution: 10 Hz Accuracy: +/- 120 ppm
Additonal Transmitter Functions
SF Skip: Transmitter skips 2600 +/- 150 Hz. Four Pre-set Frequencies: Normally 404, 1004, 2804 and 2713 Hz. User can temporarily change these and the SF Skip center frequency.
Receiver Frequency
Range: 50 to 99999 Hz Resolution: 1 Hz Accuracy: +/- 1 Hz
Range: 10 to 200 kHz Resolution: 10 Hz Accuracy: +/- 10 Hz
Transmitter Level
Range: -40 to +13 dBm. Resolution: 0.1 dB. Accuracy at 1004 Hz, 0 to -19 dBm: Typically +/-0.1 dB.
Flatness (dB relative to 1004 Hz)
Level (dBm) +10 to +13 Frequency (Hz): 0-200 level: +1 -2.5* 200-15k+/- 0.2* 15k-60k +/- 0.5* 60k-85k +/- 0.7* 85k-200k +/- 1.5*
Level (dBm) -40 to +10 Frequency (Hz): 20-200 level: +/- 1.0 200-15k +/- 0.2 15k-60k +/- 0.5 60k-85k +/- 0.5 85k-200k +/- 1.5* *typical
Distortion (dB down from fundamentals) Level (dBm) +10 to +13 Frequency (Hz): 50-100 level: 20* 100-4k 45* 4k-200k 45*
Level (dBm) 0 to 10 Frequency (Hz): 50-100 level: 20* 200-4k 55 4k-200k 45
Level (dBm) -30 to 0 Frequency (Hz): 50-100 level: 40* 200-4k 50 4k-200k 40
Level (dBm) -40 to -30 Frequency (Hz): 50-100 level: 40 200-4k 50 4k-200k 35*
At 1004 Hz, 0 dBm: THD *Typically > 62 dB down from fundamental.
Receiver Level Range: - 50 to + 13 dBm. Resolution: 0.1 dB. Detector Type: Average.
Accuracy (dB) Level (dBm) -13 to -40 Frequency (Hz): 50-200 level: +/- 0.5 200-15k +/- 0.2 15k-60k +/- 0.5 60k-85k +/- 0.5 85k-200k +/- 2.0*
Level (dBm) -40 to -60 Frequency (Hz): 50-200 level: +/- 0.6* 200-15k +/- 0.4* 15k-60k +/- 0.8* 60k-85k +/- 1.0* 85k-200k +/- 2.0* *Typical
At 1004 Hz, - 20 to + 13 dBm: +/- 0.1 dB. Receiver accuracy is specified from 500 Hz when using the 135 or 150 ohm terminations.
Message Circuit Noise
RECEIVER (Transmitter:off and terminated). Range: 10 to 100 dBrn (135& 150 ohm: 17 to 100 dBrn). Resolution: 1 dB. DetectorType: Quasi-RMS. Accuracy: +/-1 dB from 10 to 100 dBrn Filters: C-Message, 3 kHz Flat, 15 kHz Flat, Program , 50 kbit
Noise-with-Tone
RECEIVER (Transmitter: 1004 Hz tone). Notch Filter: > 50 dB rejection from 995 to 1025 Hz. Range: (at 600, 900 and 1200 ohm): 10 to 100 dBrn. Resolution: 1 dB. Accuracy: +/- 1 dB from 20 to 100 dBrn, +/- 3 dB from 10 to 20 Brn Detector Types: Quasi-RMS
Signal-to-Noise Ratio
RECEIVER (Transmitter: 1004 Hz tone). Signal Level Range (600, 900 and 1200 ohm): - 40 to +13dBm. Ratio Range: 10 to 45 dB. Ratio Resolution: 1 dB. Accuracy: (signal -30 to + 10 dBm), S/N 10 to 40 dB: +/- 1 dB; S/N 40 to 45 dB: +/- 2 dB. Detector Types (noise): Quasi-RMS; (tone): Average.
3-Level Impulse Noise
TRANSMITTER C-Msg or 3 kHz
Flat receive filter selected: 1004 Hz tone. Any other receive filter: off and terminated.
RECEIVER
Level Range: - 40 to + 13 dB. Notch Filter: > 50 dB rejection from 995 to 1025 Hz. Threshold Ranges (at 600 ohm): Low 30 to 100 dBrn, Mid and High 4 and 8 dB higher respectively, up to 100 dBrn. Threshold Accuracy: +/- 1dB over the following ranges: with C-Msg or 3 kHz Flat. filter: 40 to 100 dBrn; with Program filter: 60 to 100 dBrn. Loss of Holding tone: “-” sign in right display, latching. Count Timer: Nominally 5, 15, 60 minutes or non-stop. Count Range: 0 to 9999. Max Count Rate: Nominally 8 per second.
RECEIVER (Transmitter: off and terminated). Range: (at 600, 900 and 1200 ohm): 50 to 120 dBrn. Resolution: 1 dB. Accuracy: +/- 1.5 dB. Filters & Detector: See message circuit noise.
P/AR
TRANSMITTER Signal: 16 frequencies in range 140 to 3890 Hz. Level Range: - 40to 0 dBm. Resolution: 1 dB.
RECEIVER P/AR Range: 0 to 120 units, otherwise +/- 4 units Resolution: 1 unit. Accuracy: (30 to 110 units): +/- 2units. Level Range: - 40 to + 0 dBm (135 & 150W: - 30 to + 0 dBm) Resolution: 1 dB
Specifications
Maximum DC Blocking: 200V nominal.
Impedances: Nominally 135, 150, 600, 900 and 1200 ohm. Transmit and receive impedances are independently selectable.
Receiver Return Loss: (600, 900 and 1200 ohm: 50 Hz to4 kHz): Typically > 30 dB.
Bridging Loss (up to 20 kHz): Typically < 0.2dB.
Longitudinal Balance: (Typical) > 80 dB at 60 Hz, > 70 dB at 540 Hz, > 60 dB up to 4 kHz, decreasing at 6 dB per octave up to 20 kHz.
Hold Circuits: 2, each drawing 24 mA nominal.
physical Characteristics
Weight: 7.8 kg (with HP J2301B)
Dimensions: 12.2H x 31.1W x 30D cm 4.9H x 12.5W x 12D in (with HP J2301B)
Operating Conditions:
Temperature Operating: 5° C to + 40° C (+41° F to 104° F) Non- Operating - 25° C to + 60° C (-13° to 140° F)
Humidity:
Operating 20% to 80% Relative Humidity to 40° C non-condensing Storage: 10% to 90% Relative Humidity to 60° C non-condensing
Regulatory Compliances: Bears the CE and mark
HP J2527A Transmission Impairment Measuring Set includes connector for mating with the J2300/01/02A, two WECO 310 test cords and Operating Manual.
Opt 001 Replaces North American Features and Connectors with CCITT; 820/1020 Hz Holding Tone: Deletes Test Cords
W30 2 years additional hardware service: For 2-year extended hardware support beyond the standard 1-year return-to-bench warranty, order Option W30.
1A3 Bellcore CLEI compliance for Bell Operating Companies: For Bellcore Common Language Equipment Identification (CLEI) labeling, order Option 1A3.
Trademarks:
Microsoft is a U.S. registered trademark of Microsoft Corp.
HP J2527A Transmission Impairment Measurement Set
If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. |
![]() |
Related product families available online:
Page Updated: Monday October 05 19:02:08 UTC 1998