HP J2905B ISDN BRI S/T and U Interface Module

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The HP J2905B mainframe module adds ISDN testing to the HP Internet Advisor for a fully integrated monitoring simulation, call placement and BERT solution. Basic S/T and U ISDN problems can be quickly isolated. With this module the portable and integrated HP Internet Advisor is a multi-protocol, multi-interface protocol analyzer that connects to the ISDN interface: basic rate S/T and U. You can quickly isolate network problems using the complete, real-time ISDN decodes with summary and detailed displays (including full information elements) and extensive D-channel statistics.

HP Internet Advisor supports 14 different ISDN switch and country variants; extensive decodes on the user data channel allow LAN interconnect problems to be solved quickly.

With the Internet Advisor comes extensive triggering, filtering and searching which allow you to view only the information that is important to the problem at hand. Problems are solved quickly using Internet Advisor's many pre-written tests and its intuitive user-interface. Verify the integrity of the link to carry data with complete BERT testing. Check network connectivity with pre-written simulation tests. Unattended remote control allows network experts to remain at a central site rather than travel to a remote location to solve tough network problems, saving time and money.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
ISDN Test Capabilities


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Operating Characteristics

Physical Interfaces BRI S/T: ITU-T standard I.430, Euro ETS 300 012, 0 and ANSI standard T1.605. BRI U: 2B1Q ANSI standard T1.601-1992, Euro ETR 80, and ITU-T standard G960/961. BRI S/T/U: RJ-45 connectors are standard. RJ-11 handset jack standard. Voice coding supported: a-law and mu-law.


Data Rates

BRI S/T/U: D channel 16 kbps, B1 channel 56 or 64 kbps, B2 channel 56 or 64 kbps, or B1+B2 112 or 128 kbps.


Interface Status

BRI S/T Information states 0-4 stored as events in buffer. Front panel LED indicators for info States 0-4, PSI Present (normal, reverse), PS2 Present, D data, B1/B2 activity. BRI U: Signal loss, frame sync, activation achieved, sealing current, data on D channel, B1 channel and B2 channel, CRC error, far end block error, and alarm indication bit (AIB).


Monitor Specifications:

D-channel protocols Level 2: LAPD per ITU-T standard Q.921. SAPI 0 signalling, SAPI 16 X.25 packet and SAPI 63 LAPD management procedures supported.
Level 3: Q.931 Blue Book 1988, ETSI, JT-Q931, National ISDN-1, ITR6, VN3, VN4, Televerkets, TPH 1962 and 1856, AT&T 5ESS, AT&T 4ESS, Northern Telecom DMS-100, Bellcore, Siemens EWSD. B-channel protocols
WAN: LAP-B, X.25 Blue Book 1988, HDLC, SDLC, synchronous PPP and LCP, frame relay (ANSI T1.606,ITU-T I.233, ANSI T1.617 annex D, F & G, RFC 1490, ITU-T Q.933, NTT), SNA, and SNAP. These can encapsulate any of the following LAN decodes.
LAN over WAN: 802.2, 802.3, and 802.5 MAC layer
TCP/IP: IP, TCP, UDP, RIP, OSPF, ICMP, SNMP, BOOTP, EGP, NETBLT, RFCNB, SUNRPC and TFTP Novell: IPX, IPXFILE, IPXRIP, IPXSAP DECNet: DNA, MOP XNS: IDP, SPP, RIP AppleTalk: AARP, AEP, ALAP, ATP, DDP, RTMP, ZIP 3Com: NetBIOS IBM: SNA (FID0, FID2, FID4, RU, RH, Data Sense), NetBIOS, and SMB
Displays: Summary of Q.921/Q.931 decode, complete detailed decode for LAP-D, X.25 over D-channel, complete Q.931 including all information elements and diagnostic information, and full decode of user data including LAN encapsulated within any WAN protocol.
Searching and Triggering: On frame type — user defined, information, supervisory, unnumbered, RR, RNR, REJ, SABME, UI, DISC, DM, UA, FRMR, and XID. On SAPI — call control SAPI 0, Q.931 SAPI 1, X.25 SAPI 16, layer 2 management SAPI 63, or userdefinable any SAPI value from 00 hex to FF hex. On TEIvalue — enter any Hexvalue. On LAP-D — Command or response bit or poll/final bit and good, bad, or abort FCS. Or search on any user data string up to 63 bytes into theframe.
Statistics: Maximum, instantaneous, and minimum utilization as percent, maximum, instantaneous, minimum, and average throughput in kbps; total octets, data segments, total frames, bad FCS’s, abort frames, and short frames. Pre-written stats counters: Message types — counts most Q.931 message types D Channel Frames — counts D-channel frames (LAP-D, Q.931,and X.25) LAPD frame counts X.25 packet counts Disconnect causes
Note: All counters are user- modifiable. Sixteen counters are navailable for TE and 16 for NT.
Timing Measurements: Time stamp resolution 100 ns.Display delta time between any two frames, relative time from beginning of run, or absolute realtime stamp with date.


Quickly Verify Call Placement and Link Integrity


The Internet Advisor's ISDN simulation, call placement BERT testing, and numerous pre-written call placement scripts make verifying the proper operation of ISDN basic rate and primary rate circuits quick and easy.
BRI — basic rate interface simulation/call placement specifications:
Simulate: TE (terminal equipment), NT (network termination), or LT (line termination)
Emulation: LAP-D and partialQ.931
Bus Configuration: Point-to-Point,ShortPassive Bus and Extended Passive Bus Handset Support — A-law and mu-law on B1 or B2
Receiver Mode: Terminated or Bridged
BERT Channel: B1 — 56 kbps or 64 kbps B2 — 56 kbps or 64 kbps B1 and B2 — 112 kbps or 128 kbps
B1 (B2 Looped) — Full Duplex (B1 transmit to B2 receive, B2 receive to B2 transmit, B2 transmit to B1 receive) B2 (B1 Looped) — Full Duplex (B2 transmit to B1 receive, B1 receive to B1 transmit, B1 transmit to B2 receive) B1 transmit to B2 receive B2 transmit to B1 receive
TE Simulation Tests: Place voice call Place 56 kbps data call Place 64 kbps data call Place BERT call B1 to B2 BERT Call - Place call and run a loopback BERT B1 to B2 Answer call
NT Simulation Tests: Place voice call Place 56 kbps data call Place 64 kbps data call
Pre-written simulation
test support: ETSI, NI-1, JT-Q.931, CCITT, AT&T 5ESS, AT&T NI-1, DMS-100, 1TR6, VN4, Siemens, and Australia


ISDN BERT Specifications:

Patterns: 63, 511,2047, 4095, 215-1, 220-1, 223-1, QRSS, All 1’s, All 0’s, 10101010 (1:1) and any user defined pattern. User defined pattern can be hex or text up to 128 bytes in length. Standard pattern exception for CEPT-E1: 223-1 and 215-1inverted per CCITT O.151.
Test Duration: 5, 10, 15 minutes, 1, 4, 12, 24 hours, or continuous
Error insert type: Logic, BPV, and frame.
Error insert rate: 1 in 103, 1 in 104, 1 in 105, 1 in 106, 1 in 107
BERT Results: Errored seconds Errored free Seconds Percent error free seconds Total bits received count Total bit errors Bit error rate G.821 available time G.821 errored seconds G.821 degraded minutes G.821 severely errored seconds G.821 unavailable time
Logging: All BERT results may be logged to the hard drive at intervals from 1 minute up to 999hours.


Physical Characteristics

Weight: Module 0.5 kg (1 lb) With mainframe 6.8 kg (15 lbs) Dimensions: Module 15D x 12.5W x 2.5H cm (6D x 5W x 1H inches) With mainframe 8.8H x 31.3W x 30D cm (3.5H x 12.5W x 12D inches)


Operating Conditions

Temperature: Operating +5°C to +40° C (+41° F to 104°F) Non-operating -25°Cto +60°C (-13° F to 140° F)
Humidity: Operating 20% to 80% relative humidity to 40° C non-condensing Storage 10% to 90% relative humidity to 60° C non-condensing
Warranty: 3 years
Regulatory Compliances: Bears theCE mark


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP J2905B     ISDN BRI S/T and U Interface Module









Basic Rate Interface slide-in module includes software and hardware for monitoring, simulation call placement and BERT for the ISDN S/T and U interfaces for the HP J2301A, J2302A, J2301B, and J2302B.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP Internet Advisor WAN -- ISDN Test Solutions ( PDF)

If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. Get Acrobat

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right product choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Friday February 05 02:57:18 UTC 1999