HP R347B Millimeter-Wave Noise Source, R-band |
The HP R347B noise source covers a 26.5 to 40 GHz frequency range.
This waveguide noise source allows you to make accurate and convenient
noise figure measurements on millimeter-wave devices. The HP R347B
provides highly precise broadband noise at the input of the system or
component under test. The noise figure meter then processes the ON/OFF
ratio of noise power present in the system IF, and provides an accurate
reading of noise figure and gain. The HP R347B noise source has
remarkable ENR stability over time, which allows longer recalibration
cycles and more accurate noise figure measurements.
Product Specifications
Frequency Range: 26.5 to 40 GHz Excess Noise Ratio (ENR) Range 26.5 to 40 GHz: 10 to 13 dB Maximum SWR (reflection coefficient) Source Off: <1.42 (0.17) Source On: <1.31 (0.13) Power Required: 28 V +/-1 V (automatically supplied by the HP 8970B Noise Figure Meter Maximum Reverse Power: 100 mW Connectors Bias: BNC (f) Noise Output: R-Band Waveguide UG-599/U Flange ENR Variation with Temperature: <0.009 dB/°C ENR Variation with Voltage: <0.005 dB/V Switching Speed: <10 µs
General Characteristics
Operating Temperature: 0 to 55°C Dimensions: 52 mm x 108 mm x 60 mm (2.1 in x 4.3 in x 2.4 in) Weight Net: 0.21 kg (0.46 lb) Shipping: 0.36 kg (0.80 lb)
HP R347B R-Band Noise Source
Page Updated: Thursday June 19 16:13:03 UTC 1997