Radiofrequency Radiation Dosimetry Handbook - Fourth Edition

Table 9.11.
Currents Through the Wrist and Finger for Maximum SAR = 8 W/kg.

(Cross-sectional areas are for non-bony regions of respective parts of the body.)
(Gandhi et al., 1984)


Frequency (kHz)
Conductivity of Muscle* (S/m) Current Density (A/m2) Wrist (cross-sectional area = 17 x 10-4 m2)** Finger (cross-sectional area = 1.22 x 10-4 m2)***
10 0.132 32.5 55.2 3.96
100 0.494 62.9 106.9 7.67
1000 0.550 66.3 112.7 8.09



* From Durney et al., 1980.
** A. C. Eycleshymer, 1911.
*** J. Sobotta and F. H. J. Figge, 1967.

This is a Department of Defense computer system for authorized use only. DoD computer systems may be monitored for all lawful purposes, including to ensure that their use is authorized, for management of the system, to facilitate against unauthorized access, and to verify security procedures, survivability, and operational security. Using this system constitutes consent to monitoring. All information, including personal information, placed on or sent over this system may be obtained during monitoring. Unauthorized use could result in criminal prosecution.

POC: AFRL/HEDM, (210)536-6816,  DSN 240-6816