This is a tutorial for programming conventional frequencies into your PRO-89. For this example, we are programming the frequency 148.2500 into channel 3.
For additional information on this product, see the links below:
Step 1: Select the Channel Number | |
![]() |
![]() |
Press MAN, enter the channel number (1-200) where you want to store a frequency, and press MAN again. In this example, we have selected channel 3. | |
Step 2: Enter the Program Mode | |
![]() |
![]() |
Press PGM. The status changes from MAN (for manual) to PGM (for program). The L/O indicates that this channel is locked-out, which is the default for empty channels. | |
Step 3: Enter the Frequency | |
![]() |
![]() |
Use the number keys and the DELAY/. key to enter the frequency (including the decimal point) you want to store. Note that L/O is no longer on the screen. | |
Click here to purchase Frequency Lists on CD | |
Step 4: Store the Frequency | |
![]() |
![]() |
Press ENT to store the frequency into the channel. If -dUPL- appears on the display, see Step 5, below. | |
Step 5: If -dUPL- Appears on the Display | |
![]() |
![]() |
If you entered a frequency that is already stored in another
channel, the scanner beeps three times and displays the lowest channel number where the
frequency is already stored and -dUPL- and flashes. The display then goes
back to the frequency programming display (as in the previous step) and the frequency
flashes. The example above shows the -dUPL- display which would
occur if you tried to program the frequency 148.2500 into another channel after
programming it into channel 3. When it returns to the frequency programming display, you can choose to either store the frequency anyway or clear and program a different frequency. If you want to store the frequency anyway, press ENT again. If you want to clear the frequency, press MON/CL. |
|
Step 6: Set the Delay | |
![]() |
![]() |
Press DELAY/. if you want the scanner to pause 2 seconds on this channel before it proceeds to the next channel after a transmission ends. With delay set on a channel, you will see DLY in the lower right corner. | |
Step 7: Program Additional Frequencies | |
![]() |
![]() |
To program the next channel in sequence, press PGM. The scanner will move to the next channel, and you can program the next frequency by repeating from Step 3. | |
Step 8: Return to Manual Mode | |
![]() |
![]() |
When you are done, you can stop programming by pressing MAN. The display changes back to MAN. | |