HP 8496/97 Programmable and Manual Step Attenuator Family


[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Summary

Hewlett-Packard step attenuators offer exceptional repeatability and reliability in a wide range of attenuation, frequency, and connector options. Each attenuator contains three or four cascaded attenuator sections; edge-line contacts insert and remove attenuator sections as needed. Precision gold-plated leaf springs ensure long life and very high attenuator repeatability. Programmable models feature fast-switching solenoids and attenuation programming is done through a 12-pin connector.

To improve measurement accuracy in manual and automated test systems, NIST traceable data (SWR and attenuation) is available as Option 890. Generated on an HP 8510 network analyzer, this option offers swept data for each attenuator in 250 MHz steps from 1500 MHz to 26.5 GHz, depending on the model.

Related product datasheets available online:



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Features



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Specifications

Frequency Range
HP 8496A/G:			dc to 4 GHz
HP 8496B/H:			dc to 18 GHz
HP 8497K:			dc to 26.5 GHz

Incremental Attenuation:	0 to 110 dB, 10 dB steps
HP 8497K:			0 to 90 dB, 10 dB steps

SWR Maximum (50 ohms nominal)
HP 8496A/G:			1.5
HP 8496B/H
	dc to 8 GHz:		1.5
	dc to 12.4 GHz:		1.6
	dc to 18 GHz:		1.9
HP 8497K
	dc to 6 GHz:		1.25
	6 to 12.4 GHz:		1.45
	12.4 to 18 GHz:		1.6
	18 to 26.5 GHz:		1.8

Insertion Loss (0 dB Setting):	0.6 dB + 0.09 dB/GHz

Attenuation Accuracy
HP 8496A/G:			±1.7% of setting or ±0.4 dB
				whichever is greater
HP 8496B/H
	dc to 12.4 GHz:		±3% (% in dB from attentuation setting)
	dc to 18 GHz:		±4% (% in dB from attentuation setting)		
HP 8497K
	at 6 GHz:		±0.3 dB (10 dB attenuation)
	at 26.5 GHz:		±2.8 dB (90 dB attenuation)

Power Rating
Average:			1 W
Peak:				100 W
Speed:				10 µs maximum

Minimum Life:			5 million cycles per section

Solenoid
HP 8496G/H
	Voltage:		20 to 30 V
	Speed:			<20 ms
	Power:			2.7 W
HP 8497K
	Voltage:		5 V or 24 V
	Speed:			<20 ms
	Power:			2.7 W

Size
HP 8496A/B:			73 mm W x 43 mm H x 159 mm D
				(2.9 in x 1.7 in x 6.2 in)
HP 8496G/H:			73 mm W x 43 mm H x 142 mm D
				(2.9 in x 1.7 in x 5.6 in)
HP 8497K:			52 mm W x 43 mm H x 143 mm D
				(2.1 in x 1.7 in x 5.6 in)

Weight:				0.9 kg (2 lb)


[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Ordering Information

HP 8496A	Manual Step Attenuator, 0 to 110 dB, 10 dB steps
HP 8496B	Manual Step Attenuator, 0 to 110 dB, 10 dB steps
HP 8496G	Programmable Step Attenuator, 0 to 110 dB, 10 dB steps
HP 8496H	Programmable Step Attenuator, 0 to 110 dB, 10 dB steps
HP 8497K	Programmable Step Attenuator, 0 to 90 dB, 10 dB steps



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

To help you make the right instrument choices



Contact HP Test & Measurement. (c) Copyright 1994, 1995, 1996, 1997 Hewlett-Packard Company.