HP 8900 Peak Power Meter Family


[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Summary

The HP 8900C and 8900D peak power meters directly display the peak power of RF pulses over a 100 MHz to 18 GHz frequency range. Measurements can be made on pulses with widths from 1 s (100 ns in compare mode) to CW, and repetition rates from 100 Hz (0 Hz in compare mode ) to 100 kHz. The 8900C is an economical analog meter calibrated in watts and dBm. The analog display with its large, easy-to-read scale makes it simple to measure peak or null-pulsed power systems. The HP 8900D has a high resolution 3 1/2-digit digital display calibrated in watts. The direct reading display and range annunciators make the digital version a good choice for production and field applications where unambiguous or frequent readings are required.

Related product datasheets available online:



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Features



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Specifications

HP 8900C/D Specifications

Frequency Range: 100 MHz to 18 GHz Dynamic Range: 20 dB (0 to +20 dBm) HP 8900C: 4 ranges of 3, 10, 30, and 100 mW full scale HP 8900D: 2 ranges of 10 and 100 mW full scale Pulse Response Direct Mode Pulse Width: 1 µs to CW Repetition Rate: 100 Hz to 100 kHz Compare Mode: Pulse Width: 100 ns (typical) limited by rise-time specification Repetition Rate: 0 to 100 kHz Rise Time: 75 ns Fall Time: 125 ns (as measured on video output) Power Consumption: 100 and 120 Vac +5, -10% 48 to 66 Hz and 360 to 440 Hz 220 and 240 Vac +5, -10%, 48 to 66 Hz Meter Accuracy Transfer Accuracy CW Pulse CW to Pulse ----------------------------------------------------------------- Direct ±0.2 dB ±0.35 dB ±0.2 dB Compare ±0.2 dB ±0.25 dB ±0.1 dB

HP 84811A Peak Power Sensor Specifications

Power Range: 0 to +20 dBm (1 mW to 100 mW) FrequencyRange: 100 MHz to 18 GHz SWR 100 MHz to 12 GHz: <1.5 12 GHz to 18 GHz: <2.0 Maximum Peak Power: +24 dBm (250 mW) for 5 minutes Connector Type: N (male) Calibration Accuracy (+10 to 40°C)¹ 0.1 to 12 GHz: ±0.7 dB 12 to 18 GHz: ±1.0 dB ¹0 to 10°C and 40 to 55°C: add ±0.2 dB


[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Ordering Information

HP 8900C	Analog Peak Power Meter
HP 8900D	Digital Peak Power Meter
   Opt W30	Extended Repair Service
   Opt W32	Calibration Service
HP 84811A	Peak Power Sensor
   Opt W30	Extended Repair Service
   Opt W32	Calibration Service



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

To help you make the right instrument choices



Contact HP Test & Measurement. (c) Copyright 1994, 1995, 1996, 1997 Hewlett-Packard Company.

Page Updated: Thursday June 19 16:09:52 UTC 1997