Parametric Table Parametric Table
Temperature Min (deg C) , -40 
Temperature Max (deg C) 70, 85 
Data Rate (Mbps) 400 
Supply Voltage (Volt)
OtherSupply Voltage 5V or -5.2V 
Supply Current (mA) 105 
OtherSupply Current
Output Swing (Volt) .80 
Power Dissipation (Watt) .85, .50 
Jitter (ps) 50, 130 
Rise/Fall Times (ps) 250, 230 

Datasheet

TitleSize in KbytesDate
View Online

Download

Receive via Email
CLC016 Data Retiming PLL with Automatic Rate Selection 451 Kbytes 12-Aug-02 View Online Download Receive via Email
CLC016 Data Retiming PLL with Automatic Rate Selection (JAPANESE)
321 Kbytes   View Online Download Receive via Email

If you have trouble printing or viewing PDF file(s), see Printing Problems.

Package Availability, Models, Samples & Pricing

Part NumberPackageStatusModelsSamples &
Electronic
Orders
Budgetary PricingStd
Pack
Size
Package
Marking
TypePinsMSL/Lead-Free AvailabilityLead
Time
QtySPICEIBISQty$US each
SD901EVKevaluation boardPreliminaryN/AN/A 1+$250.001-
6-8 weeks0
CLC016MTCTSSOP28StatusFull productionN/AN/A24 Hour Samples
Buy Now
1K+$17.40rail
of
48
NSUZXYTT
CLC016MTC
3-8 weeks3000
CLC016ACQPLCC28StatusFull productionN/AN/A24 Hour Samples
Buy Now
1K+$17.40rail
of
35
NSUZXYYTT
CLC016ACQ
3-6 weeks3000
CLC016AJQPLCC28StatusFull productionN/AN/A24 Hour Samples
Buy Now
1K+$19.40rail
of
35
NSUZXYYTT
CLC016AJQ
3-4 weeks500
CLC016AJQ-TR13PLCC28StatusFull productionN/AN/A 
Buy Now
1K+$19.40reel
of
750
NSUZXYYTT
CLC016AJQ
3-4 weeks5000

General Description

National's Comlinear CLC016 is a low-cost, monolithic, data retiming phase-locked loop (PLL) designed for high-speed serial clock and data recovery. The CLC016 simplifies high-speed data recovery in multi-rate systems by incorporating auto-rate select (ARS) circuitry on chip. This function allows the user to configure the CLC016 to recognize up to four different data rates and automatically adjust to provide accurate, low-jitter clock and data recovery. A single resistor is used to set each data rate anywhere between 40 Mbps and 400 Mbps. No potentiometers, crystals, or other external ICs are required to set the rate.

The CLC016 has output jitter of only 130 pspp at a 270 Mbps data rate and 0.25% fractional loop bandwidth. Low phase detector output offset and low VCO injection combine to ensure that the CLC016 does not generate bit errors or large phase transients in response to extreme fluctuations in data transition density. The result is improved performance when handling the pathological patterns inherent in the SMPTE 259M video industry standard.

The carrier detect and output mute functions may be used together to automatically latch the outputs when no data is present, preventing random transitions. The external loop filter allows the user to tailor the loop response to the specific application needs. The CLC016 will operate with either +5V or -5.2V power supplies. The serial data inputs and outputs, as well as the recovered clock outputs, allow single- or differential-ECL interfacing. The logic control inputs are TTL-compatible.

Features

  • Retimed data output
  • Recovered clock output
  • Auto and manual rate select modes
  • Four user-configurable data rates
  • No potentiometers required
  • External loop bandwidth control
  • Frequency detector for lock acquisition
  • Carrier detect output
  • Output MUTE function
  • Single supply operation: +5V or -5.2V
  • Low cost

Key Specification

  • Low jitter: 130 pspp @ 270 Mbps, 0.25% fractional loop bandwidth (0.675 MHz)
  • High data rates: 40 Mbps - 400 Mbps
  • Low supply current: 100 mA, including output biasing
  • Flexible fractional loop bandwidth: from 0.05% to 0.5%

Applications

  • SMPTE 259M serial digital interfaces: NTSC/PAL, 4:2:2 component, 360 Mbps wide screen
  • Serial digital video routing and distribution
  • Clock and data recovery for high-speed data transmission
  • Re-synchronization of serial data for SONET/SDH, ATM, CAD networks, medical and industrial imaging

Reliability Metrics

Part Number Process Early Failure Rate - Rejects Sample Size (EFR) PPM * Rel. Rejects Device Hours Long Term Failure Rates (FITS) MTTF
CLC016ACQABIC41200033407500005212054006
CLC016AJQABIC41200033407500005212054006
CLC016AJQ-TR13ABIC41200033407500005212054006
CLC016MTCABIC41200033407500005212054006
SD901EVKABIC41200033407500005212054006

For more information on Reliablitity Metrics, please click here.


Design Tools

TitleSize in KbytesDate
View Online

Download

Receive via Email
SD901EVK evaluation kit 2 Kbytes 28-Jul-2003 View    

If you have trouble printing or viewing PDF file(s), see Printing Problems.

Application Notes

TitleSize in KbytesDate
View Online

Download

Receive via Email
CLC018EB: CLC018EB CLC018 Evaluation Board 495 Kbytes 6-Feb-98 View Online Download Receive via Email
CLC018EB CLC018 Evaluation Board (JAPANESE)
428 Kbytes   View Online Download Receive via Email
AN-1113: Application Note 1113 Serial Digital Video and Interface RAPIDESIGNER Operation and Applications Guide 99 Kbytes 19-May-99 View Online Download Receive via Email

If you have trouble printing or viewing PDF file(s), see Printing Problems.

[Information as of 15-Jan-2004]